064296 美國戴安Dionex ProSwift RP Protein Column 生物色譜柱
如果您對該產(chǎn)品感興趣的話,可以
產(chǎn)品名稱: 064296 美國戴安Dionex ProSwift RP Protein Column 生物色譜柱
產(chǎn)品型號: 064296
產(chǎn)品展商: 戴安Dionex
產(chǎn)品文檔: 無相關(guān)文檔
簡單介紹
戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其市場占有率達(dá)80%。全球與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。
戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對10g樣品的萃取,該技術(shù)已在環(huán)境、**、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。
064296 美國戴安Dionex ProSwift RP Protein Column 生物色譜柱
的詳細(xì)介紹
Monolith Reversed-Phase Columns for High-Resolution Protein Separations at High Flow Rates
ProSwift® reversed-phase monolith columns uniquely provide the advantages of high
resolution at exceptionally high flow rates for protein separations.
They deliver the outstanding resolving power of nonporous analytical
media combined with faster separations than any bead based columns
available. ProSwift polymer monolith columns achieve long column
lifetime, exhibit reproducibility even after hundreds of runs, and have
broad pH stability, providing high stringent wash capability.
-
High resolution at high speed
-
Highest operational flow rates available
-
High throughput and improved productivity
-
Optimal performance in a broad range of applications
-
Excellent stability over a wide pH range of 1 to 14
-
Outstanding reproducibility and ruggedness
-
High stringent wash compatible, for example, 1 M NaOH
-
High loading capacity
ProSwift
polymer monolith media are uniquely suited for the separation of
proteins. Each monolith is a single cylindrical polymer rod containing
an uninterrupted, interconnected network of flow-through channels of a
specific pore size. These large channels and the monolith’s nonporous
surfaces result in fast mass transfer for high-resolution and fast
protein separations. The channels also produce low backpressure,
allowing the use of higher linear velocities with minimal loss of
resolution.
ProSwift Reversed-Phase Monolith Columns Specifications
|
Column Name
|
Proswift RP-15
|
Proswift RP-2H
|
ProSwift RP-3U
|
Proswift RP-4H
|
ProSwift RP-10R
|
Column Dimensions
|
4.6 × 50 mm
|
4.6 × 50 mm
|
4.6 × 50 mm
|
1 × 50 mm
|
1 × 250 mm
|
1 × 50 mm
|
Base Matrix Material
|
Polystyrene-divinlbenzene
|
Surface Chemistry
|
Phenyl
|
Protein Binding
Capacity per mL of Polymer
|
3.0 mg/mL Lysozyme
|
1.0 mg/ml Lysozyme
|
.05 mg/ml Lysozyme
|
2.3 mg/ml Lysozyme
|
n.d.*
|
Protein binding capacity per column
|
2.2 mg Lysozyme
|
0.8 mg Lysozyme
|
0.3 mg Lysozyme
|
0.1 mg Lysozyme
|
0.5 mg Lysozyme
|
n.d.
|
Bed Height
|
46 mm
|
44 mm
|
40 mm
|
50 mm
|
250 mm
|
50 mm
|
Bed Volume (mL)
|
0.76 mL
|
0.73 mL
|
0.65 mL
|
0.039 mL
|
0.196 mL
|
0.039 mL
|
pH Range
|
1–14
|
1–10
|
Recommended Flow Rate
|
0.5–4 mL/min
|
1–10 mL/min
|
1–16 mL/min
|
0.1–0.4 mL/min
|
0.1–0.3 mL/min
|
40–60 μL/min
|
Maximum Flow Rate
|
5 mL/min
|
14 mL/min
|
20 mL/min
|
0.5 mL/min
|
0.4 mL/min
|
100 μL/min
|
Maximum Pressure
|
2800 psi
19.3 MPa
|
<2000 psi
13.8 Mpa
|
3000 psi
20.7 MPa
|
4350 psi
30 MPa
|
Operating Pressure
|
< 1500 psi
10.4 MPa
|
< 2500 psi
17.5 MPa
|
2900 psi
20 MPa
|
Temperature
|
70 °C
|
80 °C
|
Solvent Compatability
|
Most Common organic solvents
|
Analytical Columns
|
ProSwift RP-2H Monolith Column (4.6 x 50 mm)
|
064296
|
ProSwift RP-1S Monolith Column (4.6 x 50 mm)
|
064297
|
ProSwift RP-3U Monolith Column (4.6 x 50 mm)
|
064298
|
ProSwift RP-4H Monolith Column (1.0 x 250mm)
|
066640
|
ProSwift RP-4H Monolith Column (1.0 x 50mm)
|
069477
|
ProSwift RP-10R Monolithic Capillary Column, 1 mm i.d. × 5 cm, nanoViper
|
164586
|