CarboPac SA10 Column
for Fast, High-Resolution Mono- and Disaccharide Analysis
The
Thermo Scientific Dionex CarboPac SA10 column line has been expanded to
include a new 2 × 250 mm microbore column. This microbore column
complements the already available standard-bore Dionex CarboPac SA10 (4 ×
250 mm) Column. The new 2 mm format is optimally suitable for
interfacing with Mass Spectrometric Detectors, as well as Pulsed
Amperometric Detectors.
The Dionex CarboPac SA10 anion-exchange
column is designed for fast chromatographic analysis of simple sugars in
biofuel and food samples. The fast, efficient separations of mono- and
disaccharides are achieved without compromising resolution. The Dionex
CarboPac SA10 column can analyze six common sugars in food samples in
only 10 min, or eight common biofuel mono- and disaccharides in less
than 10 min.
-
Fast analysis
-
High resolution
-
High capacity
-
High reproducibility
-
No derivatization required
The
Dionex CarboPac SA10 column is composed of a unique macroporous
substrate coated with a strong anion-exchange layer of latex nano beads
which provides high capacity and rapid high-resolution separations. The
excellent resolution and linearity of this column provides highly
accurate, quantitative carbohydrate analysis. Used in conjunction with
pulsed amperometric detection (PAD) systems, the Dionex CarboPac SA10
column provides direct quantification of nonderivatized carbohydrates
with minimal sample preparation or cleanup, and is capable of separating
a wide range of sample concentrations. This column features high
reproducibility, and can withstand thousands of injection cycles under
high pH conditions.
CarboPac SA10 Column for Monosaccharide and Disaccharide Analysis Specifications
|
Dimensions
|
CarboPac SA10 Analytical Column:
4 × 250 mm and 2 × 250 mm
CarboPac SA10 Guard Column:
4 × 50 mm and 2 × 50 mm
|
Maximum operating pressure
|
3500 psi (24.5 MPa)
|
Temperature range
|
4–60 °C
|
Typical operating conditions
|
1700 psi at 1.5 mL/min (standard-bore column) or 0.38 mL/min (microbore column)
Recommended flow rate: 1.5 mL/min (standard-bore) or 0.38 mL/min (microbore)
|
Typical Eluents
|
Potassium hydroxide or sodium hydroxide
|
Resin composition
|
6-μm
diameter substrate (ethylvinylbenzene 55% crosslinked with
divinylbenzene) agglomerated with 55-nm MicroBead difunctional
quaternary ammonium ion (4.5% cross-linked).
|
Anion-exchange capacity
|
Approximately 290 μeq/column (4 × 250 mm standard-bore column)
Approximately 73 μeq/column (2 × 250 mm microbore column)
|
Column construction
|
PEEK
|
Analytical Columns
|
CarboPac SA10 Analytical Column (4 x 250mm)
|
074641
|
Dionex CarboPac SA10 Analytical Column (2 x 250 mm)
|
082322
|
Guard Columns
|
CarboPac SA10 Guard Column (4 x 50mm)
|
074902
|
Dionex CarboPac SA10 Guard Column (2 x 50 mm)
|
082323
|